Bostrig - Oil Rig Cables

Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs, marine vessels and oil and gas drilling rigs.

Type P cables have excellent resistance to oil, abrasion, moisture, sunlight and ester-based mud (Type P-MR).

They are suitable for use in Class I, Division I and Zone I applications and meet the crush and impact resistance requirements (C&IR) of UL 2225. (Armored & sheathed version only.)

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexible design. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored and sheathed version and unarmored version.

Click to view spec sheet: multi-conductor/armored and sheathed 12 & 10 AWG/600V or 0.6/1kV
ECS Catalogue Number TYPE Sheath Thickness Cable Diameter (Nominal) Cable Weight (Approximate) COLOUR PUT-UPS (Length)
(Inches) (mm) (inches) (mm) (lbs/1000ft) (kg/km)
BR12-01C
SP-12 0.030 0.76 0.151 3.8 28 42 BLK LONG LENGTHS
multi-conductor/armored and sheathed 12 & 10 AWG/600V or 0.6/1kV
Click to view spec sheet: multi-conductor/unarmored 12 & 10 AWG/600V or 0.6/1kV
ECS Catalogue Number TYPE NO. Insulation Thickness Sheath Thickness Diameter Cable Weight COLOUR PUT-UPS (Length)
(inches) (mm) (Inches) (mm) (inches) (mm) (lbs/1000ft) (kg/km)
BR12-03C
C12PN-3 3 0.030 0.76 0.060 1.5 0.440 11.2 135 201 BLK LONG LENGTHS
BR12-04C
C12PN-4 4 0.030 0.76 0.060 1.5 0.475 12.1 155 231 BLK LONG LENGTHS
BR12-05C
C12PN-5 5 0.030 0.76 0.060 1.5 0.525 13.3 190 283 BLK LONG LENGTHS
BR12-06C
C12PN-6 6 0.030 0.76 0.060 1.5 0.570 14.5 220 327 BLK LONG LENGTHS
BR12-10C
C12PN-10 10 0.030 0.76 0.060 1.5 0.720 18.3 355 528 BLK LONG LENGTHS
BR12-20C
C12PN-20 20 0.030 0.76 0.080 2.0 0.955 24.3 680 1,012 BLK LONG LENGTHS
BR10-02C
C10PN-2 2 0.030 0.76 0.060 1.5 0.490 12.5 115 171 BLK LONG LENGTHS
BR10-03C
C10PN-3 3 0.030 0.76 0.060 1.5 0.520 13.2 200 298 BLK LONG LENGTHS
BR10-04C
C10PN-4 4 0.030 0.76 0.060 1.5 0.565 14.4 240 357 BLK LONG LENGTHS
BR10-05C
C10PN-5 5 0.030 0.76 0.060 1.5 0.620 15.8 295 439 BLK LONG LENGTHS
multi-conductor/unarmored 12 & 10 AWG/600V or 0.6/1kV
Click to view spec sheet: multi-conductor/unarmored 14 AWG/600V or 0.6/1kV 1.94 mm2
ECS Catalogue Number TYPE NO. Insulation Thickness Sheath Thickness Diameter Cable Weight COLOUR PUT-UPS (Length)
(inches) (mm) (Inches) (mm) (inches) (mm) (lbs/1000ft) (kg/km)
BR14-03C
C14PN-3 3 0.030 0.76 0.060 1.5 0.390 9.9 100 149 BLK LONG LENGTHS
BR14-04C
C14PN-4 4 0.030 0.76 0.060 1.5 0.430 10.9 115 171 BLK LONG LENGTHS
BR14-05C
C14PN-5 5 0.030 0.76 0.060 1.5 0.475 12.1 147 218 BLK LONG LENGTHS
BR14-07C
C14PN-7 7 0.030 0.76 0.060 1.5 0.515 13.1 180 268 BLK LONG LENGTHS
BR14-10C
C14PN-10 10 0.030 0.76 0.060 1.5 0.650 16.5 260 387 BLK LONG LENGTHS
BR14-20C
C14PN-20 20 0.030 0.76 0.060 1.5 0.820 20.8 495 737 BLK LONG LENGTHS
BR14-37C
C14PN-37 37 0.030 0.76 0.080 2 1.080 27.4 850 1,265 BLK LONG LENGTHS
multi-conductor/unarmored 14 AWG/600V or 0.6/1kV 1.94 mm2
Click to view spec sheet: multi-conductor/armored and sheathed 14 AWG/600V or 0.6/1kV 1.94 mm2
ECS Catalogue Number TYPE NO. Insulation Thickness Sheath Thickness Diameter Cable Weight COLOUR PUT-UPS (Length)
(inches) (mm) (Inches) (mm) (inches) (mm) (lbs/1000ft) (kg/km)
BRP14-02CBAB
C14PNBS-2 2 0.030 0.76 0.060 1.5 0.560 14.2 205 305 BLK LONG LENGTHS
multi-conductor/armored and sheathed 14 AWG/600V or 0.6/1kV 1.94 mm2
Click to view spec sheet: multi-conductor/unarmored 16 AWG/600V or 0.6/1kV 1.23 mm2
ECS Catalogue Number TYPE NO. Insulation Thickness Sheath Thickness Diameter Cable Weight COLOUR PUT-UPS (Length)
(inches) (mm) (Inches) (mm) (inches) (mm) (lbs/1000ft) (kg/km)
BR16-10C
C16PN-10 10 0.030 0.76 0.060 1.5 0.595 15.1 200 298 BLK LONG LENGTHS
BR16-37C
C16PN-37 37 0.030 0.76     0.985 25.0 625 930 BLK LONG LENGTHS
multi-conductor/unarmored 16 AWG/600V or 0.6/1kV 1.23 mm2
Click to view spec sheet: multi-conductor/unarmored 18 AWG/600V or 0.6/1kV 0.96 mm2
ECS Catalogue Number TYPE NO. Insulation Thickness Jacket Thickness Diameter Cable Weight COLOUR PUT-UPS (Length)
(inches) (mm) (inches) (mm) (inches) (mm) (lbs/1000ft) (kg/km)
BR18-02C
C18PN-2 2 0.030 0.76 0.060 1.5 0.340 8.6 55 82 BLK LONG LENGTHS
BR18-03C
C18PN-3 3 0.030 0.76 0.060 1.5 0.360 9.1 70 104 BLK LONG LENGTHS
multi-conductor/unarmored 18 AWG/600V or 0.6/1kV 0.96 mm2
Click to view spec sheet: Single conductor/unarmored 18 AWG to 1111 MCM/ 600V or 600/1000V
ECS Catalogue Number TYPE Conductor Size Sheath Thickness Cable Diameter (Nominal) Impedance (Phase-Neutral) Inductance Capacitance Calculated Ampacity Cable Weight (Approximate) COLOUR PUT-UPS (Length)
(measured @ Deg C)
AWG OR MCM mm2 (Inches) (mm) (inches) (mm) (Ω/kft) (Ω/km) (mH/kft) (mH/km) (pF/ft) (pF/m) 95 100 110C (lbs/1000ft) (kg/km)
BR16-01C
SP-16 16   0.030 0.76 0.119 3.0 4.5 14.8 0.18 0.6 65 213 20 23 25 13 19 BLK LONG LENGTHS
BR12-01C
SP-12 12   0.030 0.76 0.151 3.8 1.9 6.2 0.15 0.5 90 295 38 45 49 28 42 BLK LONG LENGTHS
BR10-01C
SP-10 10   0.030 0.76 0.180 4.6 1.2 3.9 0.14 0.5 107 351 51 58 61 44 65 BLK LONG LENGTHS
BR08-01C-2KV
SP2KV-8 8   0.055 1.40 0.265 6.7 0.695 2.28 0.108 0.354 82 269 67 72 77 74 111 BLK LONG LENGTHS
BR06-01C-2KV
SP2KV-6 6   0.055 1.40 0.326 8.3 0.442 1.45 0.099 0.324 108 354 90 96 103 110 164 BLK LONG LENGTHS
BR04-01C-2KV
SP2KV-4 4   0.055 1.40 0.38 9.7 0.277 0.91 0.095 0.312 131 430 122 128 137 170 254 BLK LONG LENGTHS
BR02-01C-2KV
SP2KV-2 2   0.055 1.40 0.449 11.4 0.176 0.58 0.090 0.295 160 525 162 169 181 251 374 BLK LONG LENGTHS
BR002-01-2KV
SP2KV-2/0 2/0   0.065 1.65 0.594 15.1 0.092 0.30 0.088 0.289 184 604 250 262 281 499 742 BLK LONG LENGTHS
BR003-01C-2KV
SP2KV-3/0 3/0   0.065 1.65 0.684 17.4 0.075 0.25 0.086 0.282 216 708 304 300 321 668 994 BLK LONG LENGTHS
BR004-01C-2KV
SP2KV(HD)-4/0 4/0 112.6 0.105 2.7 0.821 20.9 0.07 0.2 0.11 0.4 146 479 344 351 376 896 1,333 BLK LONG LENGTHS
BR262-01C
SP2KV(HD)-262 262 133.1 0.105 2.7 0.895 22.7 0.06 0.2 0.10 0.3 162 531 382 407 436 1,035 1,540 BLK LONG LENGTHS
BR313-01C
SP2KV(HD)-313 313 158.7 0.105 2.7 0.966 24.5 0.06 0.2 0.10 0.3 175 574 426 455 487 1,227 1,826 BLK LONG LENGTHS
BR373-01C
SP2KV(HD)-373 373 189.2 0.105 2.7 1.033 26.2 0.05 0.2 0.10 0.3 189 620 476 516 553 1,424 2,119 BLK LONG LENGTHS
BR444-01C
SP2KV(HD)-444 444 225.2 0.105 2.7 1.114 28.3 0.05 0.2 0.10 0.3 205 672 531 588 630 1,707 2,540 BLK LONG LENGTHS
BR535-01C
SP2KV(HD)-535 535 271.3 0.120 3.1 1.227 31.2 0.04 0.1 0.10 0.3 200 656 596 630 675 2,025 3,014 BLK LONG LENGTHS
BR646-01C
SP2KV(HD)-646 646 327.5 0.120 3.1 1.331 33.3 0.04 0.1 0.10 0.3 216 708 670 731 783 2,429 3,615 BLK LONG LENGTHS
BR777-01C
SP2KV(HD)-777 777 394.2 0.120 3.1 1.424 36.2 0.04 0.1 0.10 0.3 236 774 754 822 881 2,896 4,310 BLK LONG LENGTHS
Single conductor/unarmored 18 AWG to 1111 MCM/ 600V or 600/1000V
Click to view spec sheet: Single conductor/unarmored 18 AWG to 1111 MCM/ 2000V
ECS Catalogue Number TYPE AWG OR MCM mm2 Sheath Thickness Diameter Impedance Inductance Capacitance 95 100 110C Cable Weight COLOUR PUT-UPS (Length)
(Inches) (mm) (inches) (mm) (Ω/kft) (Ω/km) (mH/kft) (mH/km) (pF/ft) (pF/m) (lbs/1000ft) (kg/km)
BR313-01CBAB
SPBS2KV(HD)-313 313 158.7 0.080 2.0 1.155 29.3 0.06 0.2 0.10 0.3 175 574 426 455 487 1,550 2,307 BLK LONG LENGTHS
BR444-01CBAB
SPBS2KV(HD)-444 444 225.2 0.080 2.0 1.295 32.9 0.05 0.2 0.10 0.3 205 672 531 588 630 2,065 3,073 BLK LONG LENGTHS
BR777-01CBAB
SPBS2KV(HD)-777 777 394.2 0.110 2.8 1.665 42.3 0.04 0.1 0.10 0.3 236 774 754 822 881 3,450 5,134 BLK LONG LENGTHS
Click to view spec sheet: Single conductor/armored and sheathed 8 AWG to 1111 MCM/ 2000V
ECS Catalogue Number TYPE AWG OR MCM mm2 Sheath Thickness Diameter Impedance Inductance Capacitance 95 100 110C Cable Weight COLOUR PUT-UPS (Length)
(Inches) (mm) (inches) (mm) (Ω/kft) (Ω/km) (mH/kft) (mH/km) (pF/ft) (pF/m) (lbs/1000ft) (kg/km)
BR313-01C
SP2KV(HD)-313 313 158.7 0.105 2.7 0.966 24.5 0.06 0.2 0.10 0.3 175 574 426 455 487 1,227 1,826 BLK LONG LENGTHS
BR444-01C
SP2KV(HD)-444 444 225.2 0.105 2.7 1.114 28.3 0.05 0.2 0.10 0.3 205 672 531 588 630 1,707 2,540 BLK LONG LENGTHS
BR777-01C
SP2KV(HD)-777 777 394.2 0.120 3.1 1.424 36.2 0.04 0.1 0.10 0.3 236 774 754 822 881 2,896 4,310 BLK LONG LENGTHS
Single conductor/armored and sheathed 8 AWG to 1111 MCM/ 2000V
Click to view spec sheet: three conductor/unarmored 8 AWG to 777 MCM/600V or 0.6/1KV
ECS Catalogue Number TYPE AWG OR MCM mm2 Jacket Thickness Diameter Impedance Inductance Capacitance 95 100 110C Cable Weight COLOUR PUT-UPS (Length)
(inches) (mm) (inches) (mm) (Ω/kft) (Ω/km) (mH/kft) (mH/km) (pF/ft) (pF/m) (lbs/1000ft) (kg/km)
BR06-03C
TPN-6 6 12.5 0.060 1.5 0.750 19.1 0.46 1.5 0.11 0.4 126 413 63 70 75 420 625 BLK LONG LENGTHS
BR04-03C
TPN-4 4 21.5 0.080 2.0 0.925 23.5 0.29 1.0 0.10 0.3 153 502 86 92 99 695 1,034 BLK LONG LENGTHS
BR004-03C
TPN-4/0 4/0 112.6 0.125 3.2 1.800 45.7 0.07 0.2 0.09 0.3 259 850 241 252 270 3,060 4,555 BLK LONG LENGTHS
three conductor/unarmored 8 AWG to 777 MCM/600V or 0.6/1KV
Click to view spec sheet: four conductor/unarmored 8 AWG to 777 MCM/600V or 0.6/1KV
ECS Catalogue Number TYPE AWG OR MCM mm2 Jacket Thickness Diameter Impedance Inductance Capacitance 95 100 110C Cable Weight COLOUR PUT-UPS (Length)
(inches) (mm) (inches) (mm) (Ω/kft) (Ω/km) (mH/kft) (mH/km) (pF/ft) (pF/m) (lbs/1000ft) (kg/km)
BR08-04C
FPN-8 8 7.57 0.060 1.5 0.690 17.5 0.70 2.3 0.12 0.4 95 312 47 52 56 350 521 BLK LONG LENGTHS
BR06-04C
FPN-6 6 12.5 0.060 1.5 0.820 20.8 0.46 1.5 0.11 0.4 126 413 63 70 75 540 804 BLK LONG LENGTHS
BR04-04C
FPN-4 4 21.5 0.080 2.0 1.020 25.9 0.29 1.0 0.10 0.3 153 502 86 92 99 885 1,317 BLK LONG LENGTHS
BR02-04
FPN-2 2 30.7 0.080 2.0 1.160 29.5 0.18 0.6 0.10 0.3 187 613 111 122 131 1,170 1,741 BLK LONG LENGTHS
BR001-04C
FPN-1/0 1/0 56.3 0.110 2.8 1.510 38.4 0.12 0.4 0.09 0.3 190 623 156 164 176 2,100 3,125 BLK LONG LENGTHS
four conductor/unarmored 8 AWG to 777 MCM/600V or 0.6/1KV
Click to view spec sheet: five conductor/unarmored 8 to 4/0 AWG/600V or 0.6/1KV
ECS Catalogue Number TYPE AWG OR MCM mm2 Jacket Thickness Diameter Impedance Inductance Capacitance 95 100 110C Cable Weight COLOUR PUT-UPS (Length)
(inches) (mm) (inches) (mm) (Ω/kft) (Ω/km) (mH/kft) (mH/km) (pF/ft) (pF/m) (lbs/1000ft) (kg/km)
BR06-05C
QPN-6 6 12.5 0.080 2.0 0.955 24.3 0.46 1.5 0.11 0.4 126 413 50 56 60 700 1,042 BLK LONG LENGTHS
BR04-05C
QPN-4 4 21.5 0.080 2.0 1.125 28.6 0.29 1.0 0.10 0.3 153 502 69 74 79 1,100 1,637 BLK LONG LENGTHS
BR02-05C
QPN-2 2 30.7 0.110 2.8 1.280 32.5 0.18 0.6 0.10 0.3 187 613 89 98 105 1,450 2,158 BLK LONG LENGTHS
five conductor/unarmored 8  to 4/0 AWG/600V or 0.6/1KV
Click to view spec sheet: Overall shielded multiconductor/unarmored 20, 18 & 16 AWG/600V
ECS Catalogue Number TYPE NO. Insulation Thickness Sheath Thickness Cable Diameter (Nominal) Cable Weight (Approximate) COLOUR PUT-UPS (Length)
(inches) (mm) (Inches) (mm) (inches) (mm) (lbs/1000ft) (kg/km)
BR18-04CA1
C(OS)18PN-4 4 0.030 0.76 0.060 1.5 0.385 9.8 92 137 BLK LONG LENGTHS
BR16-04CA1
C(OS)16PN-4 4 0.030 0.76 0.060 1.5 0.400 10.2 104 155 BLK LONG LENGTHS
Overall shielded multiconductor/unarmored 20, 18 & 16 AWG/600V
Click to view spec sheet: Individual and overall shielded multipair/unarmored and sheathed 16 & 14 AWG/600V or 0.6/1kV
ECS Catalogue Number TYPE NO. OF PAIRS Insulation Thickness Sheath Thickness Diameter Cable Weight COLOUR PUT-UPS (Length)
(inches) (mm) (Inches) (mm) (inches) (mm) (lbs/1000ft) (kg/km)
BR16-01PA1
TP(OS)16PN-1 1 0.030 0.76 0.060 1.5 0.350 8.9 65 97 BLK LONG LENGTHS
BR16-02PA2
TP(IS-OS)16PN-2 2 0.030 0.76 0.060 1.5 0.620 15.6 170 253 BLK LONG LENGTHS
BR16-03PA2
TP(IS-OS)16PN-3 3 0.030 0.76 0.060 1.5 0.665 16.9 215 320 BLK LONG LENGTHS
BR16-04PA2
TP(IS-OS)16PN-4 4 0.030 0.76 0.060 1.5 0.695 17.7 240 357 BLK LONG LENGTHS
BR16-06PA2
TP(IS-OS)16PN-6 6 0.030 0.76 0.060 1.5 0.805 20.1 320 476 BLK LONG LENGTHS
BR16-12PA2
TP(IS-OS)16PN-12 12 0.030 0.76 0.080 2.0 1.065 27.1 585 871 BLK LONG LENGTHS
Individual and overall shielded multipair/unarmored and sheathed 16 & 14 AWG/600V or 0.6/1kV
Click to view spec sheet: Individual and overall shielded multipair/unarmored 20 & 18 AWG/600V or 0.6/1kV
ECS Catalogue Number TYPE NO. OF PAIRS Insulation Thickness Sheath Thickness Diameter Cable Weight COLOUR PUT-UPS (Length)
(inches) (mm) (Inches) (mm) (inches) (mm) (lbs/1000ft) (kg/km)
BR18-04PA2
TP(IS-OS)18PN-4 4 0.030 0.76 0.060 1.5 0.675 17.2 225 335 BLK LONG LENGTHS
Individual and overall shielded multipair/unarmored 20 & 18 AWG/600V or 0.6/1kV
Click to view spec sheet: Individual and overall shielded multitriad/unarmored 18 & 16 AWG/0.6/1kV
ECS Catalogue Number TYPE NO. OF TRIADS Insulation Thickness Sheath Thickness Diameter Cable Weight COLOUR PUT-UPS (Length)
(inches) (mm) (Inches) (mm) (inches) (mm) (lbs/1000ft) (kg/km)
BR16-03CA1
TP(OS)16PN-1 1 0.030 0.76 0.060 1.5 0.370 9.4 85 126 BLK LONG LENGTHS
Individual and overall shielded multitriad/unarmored 18 & 16 AWG/0.6/1kV